Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Circulation Journal ; (12): 904-907, 2017.
Article in Chinese | WPRIM | ID: wpr-662420

ABSTRACT

Objective:To evaluate the safety and efficacy of ultrasound guidance for percutaneous balloon pulmonary valvuloplasty (PBPV) in comparison with conventional X-ray guidance.Methods:Our research included in 2 groups:Ultrasound group,n=102 patients with PBPV under ultrasound guidance in our hospital from 2013-03 to 2016-08 and X-ray group,n=280 patients with PBPV under traditional X-ray guidance in our hospital at the same period of time.Post-operative effect was evaluated by echocardiography and compared between 2 groups.Results:The patients' age,body weight,pulmonary artery diameter,immediate post-operative pulmonary transvalvular pressure gradient (PTPG),the in-hospital time and cost were similar between 2 groups,P>0.05.The success rate of operation in Ultrasound group and X-ray group was 99.0% vs 100%,P=0.267.In the ultrasound group,1 patient was converted to a conventional surgery due to right ventricular outflow tract muscle spasm after dilation.The operation time in X-ray group was longer than Ultrasound group,(38.9±9.2) min vs (34.6±10.0) min,P<0.001.The X-ray exposure time was (3.9±1.2) min in X-ray group.The mean follow-up time was (25.5±13.2) months and PTPG in Ultrasound group and X-ray group were (16.2±4.3) mmHg and (15.3±4.5) mmHg,P=0.120.No serious complications as death,peripheral vascular injury,cardiac perforation and pericardial effusion occurred in either group.Conclusion:PBPV under complete ultrasound guidance may not only avoid radiation and contrast agent,but also keep the safety and efficacy of minimally invasive conventional percutaneous interventional treatment.

2.
Chinese Circulation Journal ; (12): 904-907, 2017.
Article in Chinese | WPRIM | ID: wpr-660007

ABSTRACT

Objective:To evaluate the safety and efficacy of ultrasound guidance for percutaneous balloon pulmonary valvuloplasty (PBPV) in comparison with conventional X-ray guidance.Methods:Our research included in 2 groups:Ultrasound group,n=102 patients with PBPV under ultrasound guidance in our hospital from 2013-03 to 2016-08 and X-ray group,n=280 patients with PBPV under traditional X-ray guidance in our hospital at the same period of time.Post-operative effect was evaluated by echocardiography and compared between 2 groups.Results:The patients' age,body weight,pulmonary artery diameter,immediate post-operative pulmonary transvalvular pressure gradient (PTPG),the in-hospital time and cost were similar between 2 groups,P>0.05.The success rate of operation in Ultrasound group and X-ray group was 99.0% vs 100%,P=0.267.In the ultrasound group,1 patient was converted to a conventional surgery due to right ventricular outflow tract muscle spasm after dilation.The operation time in X-ray group was longer than Ultrasound group,(38.9±9.2) min vs (34.6±10.0) min,P<0.001.The X-ray exposure time was (3.9±1.2) min in X-ray group.The mean follow-up time was (25.5±13.2) months and PTPG in Ultrasound group and X-ray group were (16.2±4.3) mmHg and (15.3±4.5) mmHg,P=0.120.No serious complications as death,peripheral vascular injury,cardiac perforation and pericardial effusion occurred in either group.Conclusion:PBPV under complete ultrasound guidance may not only avoid radiation and contrast agent,but also keep the safety and efficacy of minimally invasive conventional percutaneous interventional treatment.

SELECTION OF CITATIONS
SEARCH DETAIL